blue gradient background

Durastill Export Inc.
       PROUDLY REPRESENTS
logo: durastillWater Distillation Systems for Home, Office and Business

Analysis of Distilled Water of DURASTILL Distillers

TYPICAL RESULTS FOR DURASTILL MODELS
Test Subject Amount Spiked mg/l EPA Limit Times EPA Limit Spiked Result mg/l % Removed
Nitrate
19.3
10.0
1.93
<0.01
99.95
Chloride
303
250
1.21
<0.02
99.93
Chlorine
50
4.0
12.5
2.8
94.4
Fluoride
2.08
2.0
1.04
0.05
97.6
Coliform
1200
0.0
1200
0.0
100

- Briggs Engineering & Testing Co. Inc.

TEST RESULTS PERFORMED ON TYPICAL DURASTILL MODELS
Test Subject Amount Spiked PPM EPA Limit PPM Times EPA Limit Spiked Result PPM % Removed
Silver
4.0
0.1
40
<0.024
99.4
Arsenic
4.0
0.01
400
<0.006
99.85
Cadmium
4.0
0.005
800
<0.01
99.75
Lead
4.0
0.015
266
<0.05
98.75
Selenium
4.0
0.05
80
<0.01
99.75

 

RESULTS USING POST FILTER WITH TYPICAL DURASTILL MODELS
Test Subject Amount Spiked PPM EPA Limit PPM Times EPA Limit Spiked Result PPM % Removed
Lindane
0.531
0.0002
2655
<.0002
99.6
Endrine
0.155
0.002
77.5
<.0002
99.8
Methoxychlor
0.530
0.04
13.25
<.002
99.6
THM
66.7
0.08
833
<.01
99.2
Benzene
0.50
0.005
100
<0.15
97.0
TCE
1.0
0.005
200
<0.043
95.7

- KSTL - Kansas City Testing Labs - Kansas City, MO, USA.

< = less than (below detectible limit stated)
* = standards vary according to the average maximum daily air temperature
mg/l = milligrams per liter
ppm = parts per million
N/A = no EPA standards available
% removed are shown as worse case for line entry

Return to Learn More

© 2001-2008 Durastill Export, Inc. All rights reserved.