Analysis of Distilled Water of DURASTILL Distillers
TYPICAL RESULTS FOR DURASTILL MODELS | |||||
Test Subject | Amount Spiked mg/l | EPA Limit | Times EPA Limit Spiked | Result mg/l | % Removed |
Nitrate | 19.3 |
10 |
1.93 |
<0.01 |
>99.0 |
Chloride | 303 |
180.8 |
0.60 |
<0.2> |
>99.7 |
Chlorine | 50 |
N/A |
N/A |
2.8 |
>94.4 |
Fluoride | 2.08 |
N/A |
N/A |
0.05 |
>97.6 |
Coliform | 1200 |
0.0 |
1200 |
0.0 |
>99.9 |
- Briggs Engineering & Testing Co. Inc.
TEST RESULTS PERFORMED ON TYPICAL DURASTILL MODELS | |||||
Test Subject | Amount Spiked PPM | EPA Limit PPM | Times EPA Limit Spiked | Result PPM | % Removed |
Silver | 4.0 |
0.05 |
80 |
<0.024 |
>99.4 |
Arsenic | 4.0 |
0.05 |
80 |
<0.006 |
>99.8 |
Cadmium | 4.0 |
0.01 |
400 |
<0.01 |
>99.5 |
Lead | 4.0 |
0.05 |
80 |
<0.05 |
>98.7 |
Selenium | 4.0 |
0.01 |
400 |
<0.01 |
>99.7 |
RESULTS USING POST FILTER WITH TYPICAL DURASTILL MODELS | |||||
Test Subject | Amount Spiked PPM | EPA Limit PPM | Times EPA Limit Spiked | Result PPM | % Removed |
Lindane | 0.531 |
0.004 |
132 |
<0.0002 |
>99.6 |
Endrine | 0.155 |
0.0002 |
775 |
<0.0002 |
>99.8 |
Methoxychlor | 0.530 |
0.100 |
5.3 |
<0.002 |
>99.6 |
THM | 66.7 |
0.10 |
667 |
<0.01 |
>99.2 |
Benzine | 0.50 |
N/A |
N/A |
<0.015 |
>97.0 |
TCE | 1.0 |
N/A |
N/A |
<0.043 |
>95.7 |
- KSTL - Kansas City Testing Labs - Kansas City, MO, USA.
< = less than (below detectible limit stated)
> = greater than
* = standards vary according to average maximum daily air temperature
mg/l = milligrams per liter
ppm = parts per million
N/A = no EPA standards available
% removed are shown as worse case for line entry